Description

Pitru Industries Melt Blown Cartridge is manufactured from 100% Polypropylene construction offering excellent filtration and good thermal stability. The unique density gradient construction maximizes efficiency and minimizes pressure drop. Our imaginative generation process makes a profundity filter with prevalent execution and consistency. It is developed with multi-layers’ profundity cartridges. There are two type of PP Melt Blown Filter Cartridge: Standard PP Melt Blown Filter Cartridge (O.D : 2.5") And Big Blue PP Melt Blown Filter Cartridge (O.D : 4.00" or 4.5"). Filter Cartridge is manufactured by a qualified and experienced team of professionals employing advanced technology and latest equipment’s. Our products are available in various specifications that can be customized as per client's requirement.

Specification

Filter Media 100% Polypropylene Media
Length 10", 20", 30", 40", 50", 60", 70" & Customized
Inside Diameter 0.79"(20mm), 1"(25mm), 1.1"(28mm), 1.18"(30mm), 1.97"(50mm) & Customized
Outside Diameter 2.5"(63mm), 4"(102mm), 4.5"(114mm), 6"(152mm) & Customized
Maximum Temperature 150°F (68°C) For Polypropylene
Micron Rating 1, 3, 5, 10, 20, 25, 30, 50, 75 & 100 Micron
Initial △P (PSI) at
Flow Rate (LPM)
0.2 to 0.6 PSI at 19 to 76 LPM
(Depending on Length and Micron Rating)
Various End Cap Polypro - 226, Polypro Core/Extender, Flat/Closed, Poly-222, Fin

Advantages

  • High Filtration efficiency, consistent filtering performance.

  • Made of FDA Grade PP Material which is environmental protection, without binders, additives and lubricants.

  • Centre core for strength.

  • High flow rates.

  • Controlled process parameters for consistent product.

  • Substantial Surface Area has high stream rates.

  • Multi-Layers evaluated thickness of the broadened media catches particles all through the filtering procedure.

Flow Rate & Pressure Drop Formulas

Flow Rate (I/min) = Clean △P X Length Factor
Viscocity X Flow Factor

Clean △P = Flow Rate X Viscosity X Flow Factor
Length Factor

Notes :

  • Clean △P is m bar differential at start

  • Viscosity is centistokes

  • Flow Factor is m Bard-I/min at 1cks for 254 mm (or single)

  • Length Factor convert flow or △P from 254 mm (single length) to required cartridge length